• No results found

On the search for an intelligible comet assay descriptor

N/A
N/A
Protected

Academic year: 2022

Share "On the search for an intelligible comet assay descriptor"

Copied!
4
0
0

Laster.... (Se fulltekst nå)

Fulltekst

(1)

OPINION ARTICLE

published: 17 July 2014 doi: 10.3389/fgene.2014.00217

On the search for an intelligible comet assay descriptor

Peter Møller1*, Steffen Loft1, Clara Ersson2, Gudrun Koppen3, Maria Dusinska4and Andrew Collins5

1Section of Environmental Health, Department of Public Health, University of Copenhagen, Copenhagen, Denmark

2Department of Biosciences and Nutrition, Karolinska Institutet, Huddinge, Sweden

3Environmental Risk and Health Unit, Flemish Institute for Technological Research (VITO), Mol, Belgium

4Environmental Chemistry (MILK), Health Effects Laboratory, Norwegian Institute for Air Research (NILU), Oslo, Norway

5Department of Nutrition, Faculty of Medicine, University of Oslo, Oslo, Norway

*Correspondence: pemo@sund.ku.dk

Edited by:

Rajib Bandopadhyay, Birla Institute of Technology, India Reviewed by:

Peter Maria Eckl, University of Salzburg, Austria Cristovao F. Lima, University of Minho, Portugal Dona Sinha, Chittaranjan National Cancer Institute, India Alexander Y. Maslov, Albert Einstein College of Medicine, USA

Keywords: biomonitoring, comet assay, DNA damage, ECVAG, FPG, tail moment

The comet assay has developed over the past 30 years and today, a variety of dif- ferent DNA lesions and DNA repair can be measured by different versions of the assay (Collins, 2004). In the final step of the method, an image resembling a comet with a head (the nuclear core) and a tail (consisting of mainly single stranded DNA that has migrated out from the cell nuclei) is analyzed. The magnitude of the comet’s DNA-tail provides information about the level of DNA lesions in the cell. The results from comet assay analyses are reported using different descriptors, the most fre- quently used being percentage of DNA in the tail (%T), tail length and tail moment (the product of %T and tail length). These descriptors can be reported in different ways, i.e., as means, medians or as dis- tribution patterns. To compile the infor- mation on the migration of thousands of comets into a single value that is mean- ingful to convey to other researchers, is difficult. The solution has been practi- cal and controlled by those researchers with the longest experience with the comet assay. In this opinion paper, we revisit the search for a commonly accepted descrip- tor for DNA damage measured by the comet assay. We define the “best” comet assay descriptor as a measurement that best describes the migration of DNA in each comet in the agarose, fits the dis- tribution of comets in the gel, and con- veys the technical measurement of comets as a descriptor that other researchers can understand. It should be emphasized that

we do not embark on a mission to promote only one comet assay descriptor.

WHAT IS THE BEST DESCRIPTOR OF THE DNA MIGRATION IN THE AGAROSE GEL?

Figure 1 outlines the number of comet assay publications and certain events in the development of comet quantification.

The analysis of the comets (the final step of the assay) has progressed from the initial measurements of DNA migra- tion (length) with an eyepiece micrometer, through semi-automatic image analysis of digitized comet images by software pro- grams, to fully automatic systems with integrated tracking and image analysis of comets (Azqueta et al., 2013; Jackson et al., 2013). This equipment offers new possibil- ities to analyse comets in ways that were not previously possible. In addition, the fully (or semi-) automatic image analysis systems probably lift some of the restraints in the assay that are related to the manual measurement of each comet in the gels.

The majority of publications describing comet assay results adhere to the assump- tion that reliable information on the DNA migration in comets can be obtained by measuring %T. At an early stage, it was suggested that the tail moment gave a better description of the DNA migration than the more simple measurement of tail length or %T (Olive et al., 1990). An objection against tail moment has been that it is difficult to visualize the comets based on this descriptor. More refined

ways of describing the DNA migration in the comets (e.g., “tail inertia” or “tail pro- file”) have not caught on Hellman et al.

(1995); Bowden et al. (2003). This might have been due to the debate about tail moment or to the fact that these descrip- tors were not part of the software package for comet analysis at that time.

An alternative to the image analysis sys- tems is the visual scoring system. This is based on a simple classification of the comets into (most commonly) five differ- ent classes, depending on the appearance of the comet (Gedik et al., 1992). This way to classify comets has been shown to be reproducible between laboratories scoring the same set of slides (Garcia et al., 2004).

Although it is perceived as being less quan- titative than computer-based image anal- ysis systems, there are to the best of our knowledge no studies that have actually compared image analysis to visual scor- ing system in a systematic manner across laboratories.

WHAT IS THE BEST DESCRIPTION OF THE DISTRIBUTION OF COMETS IN A SAMPLE?

Most laboratories measure the DNA migration by software systems in 50 or more randomly selected comets per gel in a minimum of 2 gels (Tice et al., 2000).

This consensus is based on both practi- cal and statistical considerations. For the visual classification system it has been common practice to score 100 comets per gel, which is probably because it is a

www.frontiersin.org July 2014 | Volume 5 | Article 217|1

(2)

Møller et al. Intelligible comet assay descriptors

FIGURE 1 | Number of publications in PubMed using “comet assay” or “microgel electrophoresis” as search term and introduction of comet descriptors (see text for references).

relatively fast way of measuring the DNA migration and therefore one can afford the luxury of scoring more comets. However, it has been shown that increasing the number of scored comets per sample is associated with lower inter-sample varia- tion and thereby with increased statistical power (Forchhammer et al., 2008; Sharma et al., 2012). These analyzed comets are not independent since they originate from the same sample (derived from a single exper- iment or measurement point). It is there- fore common practice to regard the mean or median score of the comets originat- ing from one sample as a single value. The damage (i.e., DNA migration) levels in the analyzed comets are mostly not normally distributed. Therefore, some researchers prefer to report the data as median rather than the mean. In our experience it makes little difference in the statistical analyses whether the underlying distribution of the comets has been described by the median or mean. In fact, it can be argued that both the median and mean are rather sim- ple ways of describing the distribution. It has been shown that the underlying dis- tribution of the comets can be described by aχ2-distribution (Bauer et al., 1998).

The shape of the distribution is described as number of degrees of freedomand it is useful for the description of results that are subject to random variation. This is meaningful for the analysis of comet assay

descriptors since there are heterogeneities within the gel, where comets with pre- sumably the same level of DNA damage look different at certain positions of the gel. Nevertheless, this way of describing the underlying distribution of the comets has not been explored in detail, despite the fact that it provides a better fit of the data than the normal distribution. It has also been described that the underly- ing distribution can be fitted to a Weibull distribution, determined by two different descriptors, i.e., shape and scale (Ejchart and Sadlej-Sosnowska, 2003). This distri- bution has not been used in regular comet assay analyses, which is probably explained by the complexity of having to describe the level of DNA migration by two different values.

An often-raised question is whether the comet assay results can be analyzed by parametric tests when the underlying distribution is not normally distributed.

Here it is important to keep in mind that statistical analysis is based on a descrip- tor for each sample (with its underlying distribution, e.g., the %T). The distribu- tion of this descriptor score expressed as

%T in e.g., peripheral blood mononu- clear cells (PBMCs) from a group of humans, might be normally distributed or the data can be transformed to fol- low a normal distribution by for example log-transformation.

WHAT IS THE BEST COMET ASSAY RESULT TO REPORT TO OTHER RESEARCHERS?

There has been substantial debate over the years about which primary comet assay descriptor is the most relevant to use.

Tail length has been discarded by many researchers since the maximal DNA migra- tion is typically reached at low doses of exposure to DNA strand breaking agents (at least when analyzed with commonly used comet assay protocols). The debate about the use of %T or tail moment has diverted attention from the real issue of whether any of these descriptors are mean- ingful to researchers who are not familiar with the comet assay. These descriptors are quite seriously dependent on assay con- ditions (Azqueta et al., 2011; Ersson and Möller, 2011), and it would be more rel- evant to report DNA damage values after adjustment for the assay-specific condi- tions, typically by reference to standard curves. Nevertheless, reference values for DNA damage in terms of %T in PBMCs have been useful in human biomonitor- ing studies, which could be explained by the fact that most comet assay researchers in this specific field use similar assay conditions (Møller, 2006).

WHAT ABOUT THE USE OF A REFERENCE STANDARD?

As yet there is not a true standard in the comet assay like those that are used in chemical analyses. The use of reference standards has not yet been fully imple- mented, but it is recommended in pub- lished guidelines to use both positive and negative controls. There is no consen- sus about which agents should be used and an appropriate choice depends on the types of DNA-lesions that are measured.

For instance, the detection of oxidatively damaged DNA requires a specific positive control for this endpoint. An advantage of ionizing radiation as positive control is that it can be applied both as positive con- trol and calibration curve standard, since it is well-established how many DNA breaks a certain dose of ionizing radiation causes.

The drawback is that it requires special equipment for the exposure.

The European Standards Committee on Oxidative DNA Damage (ESCODD) performed the first inter-laboratory trial to attempt a standardization of comet

Frontiers in Genetics| Genomic Assay Technology July 2014 | Volume 5 | Article 217|2

(3)

Møller et al. Intelligible comet assay descriptors

assay on human PBMCs. This project focused on oxidatively damaged DNA that can be measured by the comet assay as formamidopyrimidine DNA glycosylase (FPG)-sensitive sites. It was shown that the standardized results (lesions/106dG of FPG sensitive sites) were similar to results obtained with other techniques (i.e., the alkaline unwinding and alkaline elution assays) (ESCODD et al., 2005). The European Comet Assay Validation Group (ECVAG) subsequently looked further into approaches to reduce inter-laboratory variation in DNA damage by the use of calibration samples for standardization of comet assay descriptors (Møller et al., 2010). ECVAG settled on describing the DNA damage as lesions/106bp rather than lesions/106dG because the comet assay can be modified to measure various types of nucleobase lesions.

The first ECVAG trial assessed varia- tion in the level of DNA strand breaks in coded cryopreserved calibration standards and test samples that had been distributed to 12 laboratories. This showed that all laboratories detected a dose-response rela- tionship in coded samples, although there were differences in the reported values.

The inter-laboratory coefficient of vari- ation was 47% when the levels of DNA strand breaks were measured as %T or comet score, whereas it was 28% after transformation to lesions/106bp via the calibration curve (Forchhammer et al., 2010). The same analysis for FPG-sensitive sites showed that the participating lab- oratories could detect a dose-response relationship in coded cell samples. The conversion of %T to lesions/106bp increased the percentage of total varia- tion explained by the inter-sample/subject variation from 49 to 73% (Johansson et al., 2010). A subsequent ECVAG trial looked into a standard comet assay protocol, but was only partly successful because some laboratories observed no difference in calibration curve samples and obtained negative values of FPG sensitive sites in human PBMCs (Forchhammer et al., 2012). ECVAG also showed that the over- all variation of FPG-sensitive sites in the PBMCs could be partitioned into inter- laboratory (56.7%), residual (42.9%), intra-laboratory (0.2%) and inter-subject (0.3%) variation (Ersson et al., 2013). The most important finding in this trial was

that the variation within each laboratory was relatively low.

Variation in DNA damage can be diminished by standardization of the pri- mary comet assay descriptor using calibra- tion samples. As highlighted by ComNet—

a network of researchers using the comet assay in human biomonitoring studies—

one of the challenges is to determine experimental factors that influence relia- bility and robustness of the comet assay as a biomonitoring tool (Collins et al., 2014).

For, these kinds of studies, it is important to have low assay variability among lab- oratories. The number of scored comets could be an important determinant in this respect. But, maybe we also have to look more ahead and think of develop- ing comet assay equipment with integrated calibration samples for standardization, and/or completely other scoring princi- ples. Still some work to be done in the next 30 years!

REFERENCES

Azqueta, A., Gutzkow, K. B., Brunborg, G., and Collins, A. R. (2011). Towards a more reliable comet assay: optimising agarose concentra- tion, unwinding time and electrophoresis conditions. Mutat. Res. 724, 41–45. doi:

10.1016/j.mrgentox.2011.05.010

Azqueta, A., Gutzkow, K. B., Priestley, C. C., Meier, S., Walker, J. S., Brunborg, G., et al. (2013). A com- parative performance test of standard, medium- and high-throughput comet assays. Toxicol.

In Vitro 27, 768–773. doi: 10.1016/j.tiv.2012.

12.006

Bauer, E., Recknagel, R.-D., Fiedler, U., Wollweber, L., Bock, C., and Greulich, K. O. (1998). The distribution of tail moments in single cell gel electrophoresis (comet assay) obeys a chi-square 2) not a gaussian distribution.Mutat. Res.398, 101–110.

Bowden, R. D., Buckwalter, M. R., McBride, J. F., Johnson, D. A., Murray, B. K., and O’Neill, K. L. (2003). Tail profile: a more accurate sys- tem for analyzing DNA damage using the comet assay.Mutat. Res.537, 1–9. doi: 10.1016/S1383- 5718(03)00056-1

Collins, A. R. (2004). The comet assay for DNA damage and repair: principles, applications, and limitations. Mol. Biotechnol. 26, 249–261. doi:

10.1385/MB:26:3:249

Collins, A., Koppen, G., Valdiglesias, V., Dusinska, M., Kruszewski, M., Møller, P., et al. (2014). The comet assay as a tool for human biomonitoring studies:

the comnet project.Mutat. Res.759, 27–39. doi:

10.1016/j.mrrev.2013.10.001

Ejchart, A., and Sadlej-Sosnowska, N. (2003).

Statistical evaluation and comparison of comet assay results. Mutat. Res. 534: 85–92. doi:

10.1016/S1383-5718(02)00250-4

Ersson, C., and Möller, L. (2011). The effects on DNA migration of altering parameters

in the comet assay protocol such as agarose density, electrophoresis conditions and dura- tions of the enzyme or the alkaline treatments.

Mutagenesis 26, 689–695. doi: 10.1093/mutage/

ger034

Ersson, C., Møller, P., Forchhammer, L., Loft, S., Azqueta, A., Godschalk, R. W. L., et al. (2013).

An ECVAG inter-laboratory validation study of the comet assay: inter- and intra-laboratory vari- ation of DNA strand breaks and FPG-sensitive sites in human mononuclear cells.Mutagenesis28, 279–286. doi: 10.1093/mutage/get001

ESCODD (European Standards Committee on Oxidative DNA Damage), Gedik, C. M., and Collins, A. (2005). Establishing the background level of base oxidation in human lymphocyte DNA: results of an inter-laboratory validation study. FASEB J. 19, 82–84. doi: 10.1096/fj.04- 1767fje

Forchhammer, L., Bräuner, E. V., Folkmann, J. K., Danielsen, P. H., Nielsen, C., Jensen, A., et al.

(2008). Variation in assessment of oxidatively damaged DNA in mononuclear blood cells by the comet assay with visual scoring.Mutagenesis23, 223–231. doi: 10.1093/mutage/gen006

Forchhammer, L., Ersson, C., Loft, S., Möller, L., Godschalk, R. W., van Schooten, F. J., et al. (2012).

Inter-laboratory variation in DNA damage using a standard comet assay protocol.Mutagenesis27, 665–672. doi: 10.1093/mutage/ges032

Forchhammer, L., Johansson, C., Loft, S., Möller, L., Godschalk, R. W., Langie, S. A., et al. (2010).

Variation in the measurement of DNA dam- age by comet assay measured by the ECVAG inter-laboratory validation trial.Mutagenesis25, 113–123. doi: 10.1093/mutage/gep048

Garcia, O., Mandina,T., Lamadrid, A. I., Diaz, A., Remigio, A., Gonzalez, Y., et al. (2004). Sensitivity and variability of visual scoring in the comet assay. results of an inter-laboratory scoring exer- cise with the use of silver staining. Mutat.

Res. 556: 25–34. doi: 10.1016/j.mrfmmm.2004.

06.035

Gedik, C. M., Ewen, S. W. B., and Collins, A. R.

(1992). Single-cell gel electrophoresis applied to the analysis of UV-C damage and its repair in human cells.Int. J. Radiat. Biol.62, 313–320. doi:

10.1080/09553009214552161

Hellman, B., Vaghef, H., and Boström, B. (1995). The concept of tail moment and tail inertia in the sin- gle cell gel electrophoresis assay.Mutat. Res.336, 123–131. doi: 10.1016/0921-8777(94)00047-A Jackson, P., Pedersen, L. M., Kyjovska, Z. O., Jacobsen,

N. R., Saber, A. T., Hougaard, K. S., et al. (2013).

Validation of freezing tissues and cells for anal- ysis of DNA strand break levels by comet assay.

Mutagenesis 28, 699–707. doi: 10.1093/mutage/

get049

Johansson, C., Møller, P., Forchhammer, L., Loft, S., Godschalk, R. W., Langie, S. A., et al. (2010). An ECVAG trial on assessment of oxidative damage to DNA measured by the comet assay.Mutagenesis25, 125–132. doi: 10.1093/mutage/gep055

Møller, P. (2006). Assessment of reference values for DNA damage detected by the comet assay in humans blood cell DNA.Mutat. Res.612, 84–104.

doi: 10.1016/j.mrrev.2005.10.001

Møller, P., Möller, L., Godschalk, R. W., and Jones, G. D. (2010). Assessment and reduction of comet

www.frontiersin.org July 2014 | Volume 5 | Article 217|3

(4)

Møller et al. Intelligible comet assay descriptors

assay variation in relation to DNA damage: studies from the European comet assay validation group.

Mutagenesis 25, 109–111. doi: 10.1093/mutage/

gep067

Olive, P. L., Banáth, J. P., and Durand, R. E. (1990).

Heterogeneity in radiation-induced DNA damage and repair in tumor and normal cells measured using the “comet” assay.Radiat. Res.122, 86–94.

Sharma, A. K., Soussaline, F., Sallette, J., and Dybdahl, M. (2012). The influence of the number of cells scored on the sensitivity in the comet assay. Mutat. Res. 749, 70–75. doi:

10.1016/j.mrgentox.2012.07.003

Tice, R. R., Agurell, E., Anderson, D., Burlinson, B., Hartmann, A., Kobayashi, H., et al. (2000).

Single cell gel/comet assay: guidelines forin vitro andin vivogenetic toxicology testing. Environ.

Mol. Mutagen.35, 206–221. doi: 10.1002/(SICI) 1098-2280(2000)35:3%3C206::AID-EM8%3E3.0.

CO;2-J

Conflict of Interest Statement:The Guest Associate Editor, Dr. Amaya Azqueta, declares that, despite having collaborated on a research project and publication with the authors, the review pro- cess was handled objectively. The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Received: 01 May 2014; paper pending published: 29 May 2014; accepted: 24 June 2014; published online: 17 July 2014.

Citation: Møller P, Loft S, Ersson C, Koppen G, Dusinska M and Collins A (2014) On the search for an intelli- gible comet assay descriptor. Front. Genet.5:217. doi:

10.3389/fgene.2014.00217

This article was submitted to Genomic Assay Technology, a section of the journal Frontiers in Genetics.

Copyright © 2014 Møller, Loft, Ersson, Koppen, Dusinska and Collins. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accor- dance with accepted academic practice. No use, distribu- tion or reproduction is permitted which does not comply with these terms.

Frontiers in Genetics| Genomic Assay Technology July 2014 | Volume 5 | Article 217|4

Referanser

RELATERTE DOKUMENTER

This is due to two factors: traded implied volatilities are currently higher than realised volatilities, and, as expected, tails are heavier when calculated using information from

Since the comet assay has been used for the evaluation of DNA damage in various animal models worldwide, the present review intends to discuss the application

The system can be implemented as follows: A web-service client runs on the user device, collecting sensor data from the device and input data from the user. The client compiles

As part of enhancing the EU’s role in both civilian and military crisis management operations, the EU therefore elaborated on the CMCO concept as an internal measure for

In April 2016, Ukraine’s President Petro Poroshenko, summing up the war experience thus far, said that the volunteer battalions had taken part in approximately 600 military

Based on the above-mentioned tensions, a recommendation for further research is to examine whether young people who have participated in the TP influence their parents and peers in

Overall, the SAB considered 60 chemicals that included: (a) 14 declared as RCAs since entry into force of the Convention; (b) chemicals identied as potential RCAs from a list of

An abstract characterisation of reduction operators Intuitively a reduction operation, in the sense intended in the present paper, is an operation that can be applied to inter-