• No results found

A third solution might be to repeal the specific classification rule for private import, but introduce a provision in section 3-2 stating which medicinal products are subject to the

In document Over grensen (sider 112-116)

Private import of medicinal products - Meeting 7 July 2016 - Topics for discussion

C. A third solution might be to repeal the specific classification rule for private import, but introduce a provision in section 3-2 stating which medicinal products are subject to the

A  exploração  de  técnicas  de  alinhamento  de  estruturas  em  imagens  de  doentes  com  esclerose  múltipla  tendo  por  base  algoritmos  computacionais,  objecto  de  estudo  desta  Dissertação,  oferece  inúmeras  oportunidades  para  futuros  desenvolvimentos.  Isto  sucede  porque,  qualquer  contribuição  que  vise  melhorar  o  diagnóstico  médico  pode  resultar  numa  utilização  mais  inteligente  e  racional  dos  recursos  presentes  nos  sistemas  de  saúde,  e  consequentemente, reflectir‐se numa melhoria na qualidade de vida dos doentes atingidos por  uma determinada patologia. 

Apesar  da  abordagem  global  adoptada  e  implementada  ao  longo  desta  Dissertação  ter  produzido  resultados  interessantes  e  promissores,  a  mesma  pode  ser  enriquecida  e  melhorada, nomeadamente, nos seguintes aspectos: 

 Elaborar  regras  para  ajustar  os  parâmetros  de  entrada  do  processo  de  alinhamento; 

 Construir uma interface gráfica com as ferramentas Qt Designer22 ou FLTK23 (Fast 

Light Toolkit), de modo a possibilitar a qualquer utilizador, o fácil uso da solução de  alinhamento desenvolvida; 

 Aumentar  a  quantidade  de  imagens  e  de  sujeitos  da  amostra,  visando  ampliar  a  representatividade  das  análises  estatísticas  e  substituir  as  representações  bidimensionais consideradas (2D) por volumes (3D); 

 Proceder à fusão de imagens de diferentes modalidades, de forma a promover a  obtenção de melhores resultados; 

 Validar o código desenvolvido com um profissional da área médica e modularizar a  ferramenta  de  forma  a  permitir  a  sua  integração,  por  exemplo,  em  soluções  desenvolvidas para segmentação de imagens médicas; 

 Aplicar algoritmos que empreguem as características das estruturas presentes nas  imagens e posteriormente comparar com os resultados obtidos neste estudo;   Empregar no código fonte dos algoritmos do ITK, mecanismos para levar a métrica 

para  muito  próximo  do  seu  valor  óptimo,  bem  como,  para  desactivar  a  amostragem e para usar todos os píxeis presentes na imagem fixa; 

 Formar  uma  base  de  dados  de  imagens  de  casos  de  doentes  atingidos  por  esclerose múltipla; 

 Testar  e  comparar  os  algoritmos  empregues  no  alinhamento  de  imagens  com  as  soluções computacionais analisadas no capítulo IV. 

Outro  aspecto  a  ter  em  conta  em  possíveis  trabalhos  futuros  relaciona‐se  com  a  forma  como  os  resultados  dos  critérios  de  similaridade  são  afectados  pelo  método  de  optimização  usado.   

22  Qt Designer: http://doc.trolltech.com/3.3/. Dispõe de um plugin que permite a sua fácil integração com o VTK.  23  FLTK: http://www.fltk.org/. 

   

REFERÊNCIAS 

 

Besl,  P.  J.  and  N.  D.  McKay  (1992).  "A  Method  for  Registration  of  3‐D  Shapes."  IEEE  Transactions on Pattern Analysis and Machine Intelligence 14(2): 239‐256. 

Bondiau,  P.  Y.,  G.  Malandain,  et  al.  (2004).  "Traitement  des  images  et  radiothérapie  =  Image  processing and radiotherapy." Cancer radiothérapie 8(2): 120‐129. 

Bookstein,  F.  L.  (1989).  "Principal  Warps:  Thin‐Plate  Splines  and  the  Decomposition  of  Deformations." IEEE Transactions on Pattern Analysis and Machine Intelligence 11(6):  567‐585. 

Bosc,  M.,  F.  Heitz,  et  al.  (2003).  "Automatic  change  detection  in  multimodal  serial  MRI:  application to multiple sclerosis lesion evolution." NeuroImage 20(2): 643‐656. 

Bricq, S., C. Collet, et al. (2008). "Unifying framework for multimodal brain MRI segmentation  based on Hidden Markov Chains." Medical Image Analysis 12(6): 639‐652. 

Brown,  L.  G.  (1992).  "A  survey  of  image  registration  techniques."  ACM  Computing  Surveys 

24(4): 325‐376. 

Cachier, P., J.‐F. Mangin, et al. (2001). Multisubject Non‐rigid Registration of Brain MRI Using  Intensity  and  Geometric  Features.  MICCAI  2001  ‐  Medical  Image  Computing  and  Computer‐Assisted Intervention. Utrecht ‐ Holland, Springer‐Verlag Berlin Heidelberg:  734‐742. 

Camara,  O.,  O.  Colliot,  et  al.  (2004).  Apport  de  contraintes  anatomiques  au  recalage  non  linéaire d’images TDM et TEP dans les régions thoraciques et abdominales. RFIA 2004 ‐  Reconnaissance des Formes et Intelligence Artificielle Toulouse, France: 797‐806.  Cherik,  S.,  H.  Mouhadjer,  et  al.  (2007).  Fusion  d’Image  Médicale  Multimodal  (IRM,  TEP).  4th 

International Conference on Computer Integrated Manufacturing CIP’2007   Chui, H. and A. Rangarajan (2003). "A new point matching algorithm for non‐rigid registration."  Computer Vision and Image Understanding 89(2‐3): 114 ‐ 141.  Clanet, M. and O. Lyon‐Caen (1998). La sclérose en plaques, John Libbey Eurotext.  Crum, W. R., T. Hartkens, et al. (2004). "Non‐rigid image registration: theory and practice." The  British Journal of Radiology 77(2): 140‐153.  Doyon, D., E. A. Cabanis, et al. (2004). IRM: imagerie par résonance magnétique, Masson.  Dugas‐Phocion, G., M. A. González, et al. (2004). HIERARCHICAL SEGMENTATION OF MULTIPLE  SCLEROSIS LESIONS IN MULTI‐SEQUENCE MRI. International Symposium on Biomedical  Imaging: From Nano to Macro (ISBI'04). IEEE. Arlington, VA, USA. 24, 25. 

Elsen,  P.  A.  v.  d.,  E.‐J.  D.  Pol,  et  al.  (1993).  "Medical  Image  Matching  ‐  A  Review  with  Classification." IEEE Engineering in Medicine and Biology 12(4): 26‐39. 

Ganser, K. A., H. Dickhaus, et al. (2004). "A deformable digital brain atlas system according to  Talairach and Tournoux." Medical Image Analysis 8: 3‐22. 

Gefen,  S.,  O.  Tretiak,  et  al.  (2004).  "Surface  Alignment  of  an  Elastic  Body  Using  a  Multiresolution  Wavelet  Representation."  IEEE  Transactions  on  Biomedical  Engineering 51(4): 1230‐1241.  Grimaud, J., Y.‐M. Zhu, et al. (2002). "Les techniques d'analyse quantitative des IRM cérébrales  : application à la sclérose en plaques." Revue neurologique 158(3): 381‐389.  Guéziec, A. P., X. Pennec, et al. (1997). "Medical Image Registration using Geometric Hashing."  IEEE Computational Science & Engineering 4(4): 29‐41.  Hajnal, J. V., D. L. G. Hill, et al. (2001). Medical image registration, CRC Press.  Hartkens, T., D. L. G. Hill, et al. (2002). Using points and surfaces to improve voxel‐based non‐ rigid  registration.  MICCAI  2002  ‐  Medical  Image  Computing  and  Computer‐Assisted  Intervention Tokyo ‐ Japan, Springer‐Verlag Berlin Heidelberg: 565‐572. 

Hellier, P. and C. Barillot (2003). "Coupling dense and landmark‐based approaches for non rigid  registration." IEEE Transactions on Medical Imaging 22(2): 217‐227. 

Hellier,  P.,  C.  Barillot,  et  al.  (2003).  "Retrospective  Evaluation  of  Intersubject  Brain  Registration." IEEE Transactions on Medical Imaging 22(9): 1120‐1130. 

Hermosillo,  G.,  C.  Chefd’Hotel,  et  al.  (2002).  "Variational  Methods  for  Multimodal  Image  Matching." International Journal of Computer Vision 50(3): 329‐343. 

Hill,  D.  L.  G.,  P.  G.  Batchelor,  et  al.  (2001).  "Medical  image  registration."  Physics  in  Medicine  and Biology 46: R1‐R45. 

Ibánez, L., W. Schroeder, et al. (2005). The ITK Software Guide, ITK. 

Jannin,  P.,  C.  Grova,  et  al.  (2001).  "Fusion  de  données  en  imagerie  medicale  :  revue  méthodologique basée sur le contexte clinique." ITBM‐RBM 22(4): 196‐215. 

Jiang,  T.,  Y.  Liu,  et  al.  (2008).  "Multimodal  Magnetic  Resonance  Imaging  for  Brain  Disorders:  Advances and Perspectives." Brain Imaging and Behavior 2(4): 249‐257. 

Johnson, H. J. and G. E. Christensen (2002). "Consistent Landmark and Intensity‐Based Image  Registration." IEEE Transactions on Medical Imaging 21(5): 450‐461. 

Karaçali,  B.  (2007).  "Information  Theoretic  Deformable  Registration  Using  Local  Image  Information." International Journal of Computer Vision 72(3): 219‐237. 

Karaçali,  B.  and  C.  Davatzikos  (2004).  "Estimating  Topology  Preserving  and  Smooth  Displacement Fields." IEEE Transactions on Medical Imaging 23(7): 868‐880. 

Klein,  A.,  J.  Andersson,  et  al.  (2009).  "Evaluation  of  14  nonlinear  deformation  algorithms  applied to human brain MRI registration." NeuroImage 46(3): 786‐802. 

Klein,  S.,  M.  Staring,  et  al.  (2010).  "elastix:  A  Toolbox  for  Intensity‐Based  Medical  Image  Registration." IEEE Transactions on Medical Imaging 29(1): 196 ‐ 205.  Kutzelnigg, A., C. F. Lucchinetti, et al. (2005). "Cortical demyelination and diffuse white matter  injury in multiple sclerosis." Brain 128(11): 2705‐2712.  Kybic, J. and M. Unsery (2003). "Fast Parametric Elastic Image Registration." IEEE Transactions  on Image Processing 12(11): 1427‐1442.  Lecoeur, J., S. P. Morissey, et al. (2008). Multiple Sclerosis Lesions Segmentation using Spectral  Gradient and Graph Cuts. MICCAI ‐ Workshop on Medical Image Analysis on Multiple  Sclerosis (validation and methodological issues), New York City, USA.  Loeckx, D., P. Slagmolen, et al. (2010). "Nonrigid Image Registration Using Conditional Mutual  Information." IEEE Transactions on Medical Imaging 29(1): 19 ‐ 29.  Loi, G., M. Dominietto, et al. (2008). "Acceptance Test of a Commercially Available Software for  Automatic  Image  Registration  of  Computed  Tomography  (CT),  Magnetic  Resonance 

In document Over grensen (sider 112-116)